ARC valve (Automatic Recirculation Control valve) is a specialized type of valve used primarily to protect centrifugal pumps from damage caused by low flow conditions. Centrifugal pumps can overheat or become damaged if the flow through them drops below a critical minimum. The ARC valve prevents this by automatically redirecting flow from the pump's discharge back to the source or tank when demand is low or zero.Centrifugal pumps transform mechanical energy into pressure energy by means of centrifugal force resulting from impeller rotation acting on the fluid within the pump. The pump requires a minimum liquid flow in order to avoid overheating. If a predefined minimum flow is not maintained, the pump can be permanently damaged. A number of different pump protection scenarios are reviewed below.
- NON RETURN SCENARIO The pump has no back-flow prevention and therefore product will flow back through it once it has stopped. A non return valve (NRV) is therefore usually placed after the outlet of the pump. A reservoir is used to take the pumps output when there is no process demand.
- CONTINUOUS FLOW SCENARIO A manual bypass or leakage path can be added to allow the required minimum flow back to the pump inlet. This system is simple and effective, but is in constant operation and therefore is inefficient and costly (energy costs).
- CONTROL VALVE SCENARIO This comprehensive control valve solution is highly effective. In this scenario, a flow control valve is connected to a flow meter and allows the main line flow to be metered. As main line flow decreases the control valve opens to allow the correct minimum flow required. However, it is a highly capital intensive solution that requires flow metering equipment, control and non return valves. No reservoir is required.
- ARV SOLUTION The previous approach stands and falls with the integrity of the control system and its associated cost. A safer system is to combine the non return valve, the bypass valve and the control valve into an interconnected unit, the so called "automatic recirculation valve". This valve closes when there is no flow, automatically opening the bypass line, which is sized for minimum flow. When the main line takes flow but less than minimum, the bypass line and the main line are both partially open.
Operation of Automatic Recirculation Control valve(ARC Valve)
The heart of the recirculation valve is a main flow sensing check valve disc, which is flow sensitive, not pressure sensitive. The disc modulates to the demand for process flow at the same time helping ensure a minimum flow through the pump. This modulating characteristic results in a consistent, stable, and repeatable performance over full pressure range.